clinuxloggingsyslog

Simultaneously write to multiple syslog facilities?


Is it possible to have one application simultaneously write to multiple syslog facilities?

I have an application, written in C/C++, that I would like to write some messages to local0 and other messages to local1. I do not want the messages for local0 to appear in local1 or vice versa.


Solution

  • Looking at the man page for syslog, I see the example:

    syslog(LOG_INFO|LOG_LOCAL2, "foobar error: %m");
    

    Does

    syslog(LOG_INFO|LOG_LOCAL0, "message for local0");
    syslog(LOG_INFO|LOG_LOCAL1, "message for local1");
    