I'm using Trace32 to debug micro controller SPC58NXXX software.
I added variables to Var.watch window and these variables values will be change once I run software.
When I run software with Lauterbach debugger even the variable values are changing the new values are not displaying in Var.watch.
I can see new variable values only when I stop debugger.
Do I need to configure in Trace32 settings for displaying variable value changes in var.watch window when debugger is in running mode?
Tell the debugger that you want it to update variable values while the processor runs. There are three methods:
%E in Var.* windows: Var.View %E myVar
Access class E: for addresses: Data.dump E:0x40070000
Global enable (not recommended): SYStem.Option.DUALPORT ON