Search code examples
angularasp.net-coreprotractore2e-testingangular-e2e

Element is not clickable at point in headless mode. But when we remove headless from protractor.conf.js it is working fine.


element(by.className('cuppa-dropdown')).element(by.className('dropdown-list')).element(by.className('list-area')).element(by.tagName('li')).click();

actually this element is in pop up. ANd it is woring fine in headless mode. But as we need to automate the test cases by build in vsts we need to execute test in headless mode

Failed: unknown error: Element is not clickable at point (863, 343) (Session info: headless chrome=63.0.3239.84) (Driver info: chromedriver=2.34.522940 (1a76f96f66e3ca7b8e57d503b4dd3bccfba87af1),platform=Windows NT 10.0.16299 x86_64)


Solution

  • As answered above try to set window size as argument for chrome

    chromeOptions: {
                    args: [
                        '--window-size=1920,1080'],
    

    and

    setTimeout(function() {
                    browser.driver.executeScript(function() {
                        return {
                            width: window.screen.availWidth,
                            height: window.screen.availHeight
                        };
                    }).then(function(result) {
                        browser.driver.manage().window().setPosition(0,0);
                        browser.driver.manage().window().setSize(result.width, result.height);
                    });
                });