I have a pluggable database in Oracle 12c named PDBORCL. After a server restart something changed in how to connect to it.
I created a user in that pluggable DB, for the example the user is PETER and the password is also PETER. Before the restart I used to be able to open a Command Prompt, run sqlplus, which would in turn ask for my username and then its password, and it would sign in. Now this does not work, it says invalid username/password. When I log in with SYS and check:
SELECT * FROM dba_users WHERE username = 'PETER';
I get no results.
However, if I sign in using the following from a command prompt, it works:
sqlplus PETER/PETER@PDBORCL
So, the DB is up and running, but it seems to be connecting by default to the wrong pluggable DB. I need to change it to the way it was before the restart, so that it connects by default to that specific pluggable DB.
How can I achieve this?
I found the solution. Change or create the environment variable LOCAL (in Windows) to PDBORCL. I think I read in linux the variable is TWO_TASK. After changing it, the following works:
sqlplus PETER/PETER