Search code examples
tizentizen-wearable-sdk

Tizen heart rate monitor rRInterval


In the Tizen Heart Rate Monitor (HumanActivityHRMData), is the value rRInterval the time of the most recent interval (and updated every heartbeat), or is it a rolling average of the last several heartbeats?

All the documentation says is:

readonly long rRInterval

Peak-to-peak interval in millisecond(s).

I'm trying to develop an app that needs a lot of precision in pulse detection, and a rolling average isn't precise enough.


Solution

  • If you are talking about HumanActivityHRMData I'm assuming you are trying the Tizen 2.3 version.

    I have tested HRM on 2.2.1.x (which is running Gear S) and the rRInterval (MotionHRMInfo) data has appeared on every beat, so I think it's the most recent interval.

    This should be the same on the newer version, but there is no hardware to test it for now.