When trying to store a user's inputed string, for part of a project, I receive the following error in spim when I simply load the file:
Immediate value is too large for field: [0x0040009c]
Below is my code:
.globl main
.data
prompt: .asciiz "0: exit, 1: enter string, 2: convert, 3: mean, 4: median, 5: display string, 6: display array: " #94 char long
enter: .asciiz "Enter string: "
.text
main:
display: addi $v0, $v0, 4 #print prompt
lui $a0, 0x1000 #grabbing prompt
syscall
addi $v0, $0, 5 #get integer
syscall
beq $v0, 0, rtn #if user type's 0, exit program
nor $0, $0, $0 #nop
beq $v0, 1, enterString #if user type's 1, enterString
nor $0, $0, $0 #nop
enterString:
addi $v0, $0, 4 #printing string
lui $a0, 0x1000 #grabbing prompt
addi $a0, $a0, 95 #grabbing enter
syscall
addi $v0, $0, 8 #grabbing input
sw $a0, 0x10000100 #storing inpuit - this specific address is a requirement
syscall
rtn: jr $ra
Now, when I run this I get the above mentioned error. However, I'm not quite sure why. It may be due to a string being 32 bit? Any explanations as to why would be appreciated. Thanks again!
I see a couple of problems in your code:
This is way longer than 94 chars:
prompt: .asciiz "0: exit, 1: enter string, 2: convert, 3: mean, 4: median, 5: display string, 6: display array: " #94 char long
Even if you remove those extra spaces, I still count 95 chars.
Don't assume that registers start out with a certain value:
addi $v0, $v0, 4 #print prompt
This should be addi $v0, $zero, 4
.
This should probably be 0x1001
, since the data section starts at 0x10010000:
lui $a0, 0x1000
Same goes for all other places where you're trying to access the data section.
I don't know if SPIM translates this into a valid instruction:
sw $a0, 0x10000100
If not, you should load the address into a register first (e.g. $a1
), and access memory through that register (e.g. sw $a0, ($a1)
).