Quickfix reset sequence number at start time but not set ResetSeqNum in Logon message


When the quickfix initiator reconnects at startTime (defined in config) it deletes the files with sequence number, but does not set ResetSeqNumFlag to Y, and the server replies with a Logout message with text "seq msg number to low ..." Is there a way to set ResetSeqNumFlag = Y only for this behavior? I don`t want to reset the sequence on every log-on.


Solution

  • This appears to be a QuickFIX/J quirk (some might consider it a bug). If ResetOnLogon=N then no ResetSeqNumFlag=Y is sent when the session start time triggers a logon. If ResetOnLogon=Y, the ResetSeqNumFlag=Y is sent on every logon. I believe this is not a big problem in practice because participants in a FIX session typically reset their sequence numbers locally after a session ends (logically ends at the end time, not a connection disconnect).

    If you want to slightly modify the source code to implement this behavior, you'd modify the quickfix.Session next() method. You could add a local flag that indicates a session has restarted (per the schedule as determined by checkSessionTime()). Pass that flag to generateLogon() and that method would use it to determine when to send ResetSeqNumFlag=Y regardless of the ResetOnLogon configuration.