I have an AIX 7.1 p650 box that has a disk array attached directly to it, on the array I have a failed disk..
PV_NAME PV STATE TOTAL PPs FREE PPs FREE DISTRIBUTION
hdisk0 missing 273 0 00..00..00..00..00
ERRPT INFO:
LABEL: DISK_ERR4
IDENTIFIER: 49A83216
Date/Time: Mon Jun 24 13:33:34 PDT 2013
Sequence Number: 3503
Machine Id: 00001501D600
Node Id: van-oppy
Class: H
Type: TEMP
WPAR: Global
Resource Name: hdisk0
Resource Class: disk
Resource Type: scsd
Location: U787B.001.DNWD723-P1-C3-T1-L1-L0
I think there is a way through SMITTY to turn on a light indicator on the array to be able to locate the failed disk, but I am not sure?
Anyone out there able to help?
Use diag
.
$ diag
<enter>
Task Selection
Hot Plug Task
SCSI Hot Swap Manager
Identify a Device Attached to a SCSI Hot Swap Enclosure Device
It should blink the LED of the device you requested.