Fellow SO users,
I'm programming my ADC (ADC0804 which is mounted on a breadboard connected to a Spartan-3 FPGA board). Now, I'm using this ADC to provide digital output for my humidity sensor. The ADC outputs an 8-bit value which I'm displaying on the LEDs on the FPGA board.
Now, I'm writing the state machine in such a way that the ADC would always continue to keep outputting values even when I vary the humidity level. But as for the current implementation I have, eventhough I'm looping back to the first state, I'm not getting a continuous stream of values. I'm only getting one 8-bit value at a time (I.E.; I have to keep pressing the reset button to update the value displayed on the LEDs). The following is my code.
FSM_NEXT_STATE_INIT : PROCESS (CLK, RST)
BEGIN
IF (RST = '1') THEN
CURR_STATE <= STARTUP;
ELSIF (CLK'EVENT AND CLK = '1') THEN
CURR_STATE <= NEXT_STATE;
END IF;
END PROCESS;
START_FSM : PROCESS (CURR_STATE, INTR)
BEGIN
CASE CURR_STATE IS
WHEN STARTUP =>
NEXT_STATE <= CONVERT;
WR <= '0';
READ_DATA <= '0';
WHEN CONVERT =>
IF (INTR = '0') THEN
NEXT_STATE <= READ1;
ELSE
NEXT_STATE <= CONVERT;
END IF;
WR <= '1';
READ_DATA <= '0';
WHEN READ1 =>
NEXT_STATE <= READ2;
WR <= '1';
READ_DATA <= '1';
WHEN READ2 =>
NEXT_STATE <= STARTUP;
WR <= '1';
READ_DATA <= '0';
WHEN OTHERS =>
NEXT_STATE <= STARTUP;
END CASE;
END PROCESS;
PROCESS (CLK, RST)
BEGIN
IF (RST = '1') THEN
Y <= (OTHERS => '0');
ELSIF (CLK'EVENT AND CLK = '1') THEN
IF (READ_DATA = '1') THEN
Y <= D7&D6&D5&D4&D3&D2&D1&D0; --Concatenate the 8-bit ADC output
END IF;
END IF;
END PROCESS;
You'll notice that in state 'READ2', I'm looping back to the beginning (so that I can keep reading values continuously as the states transition) but somehow I don't think this is working. Could anyone please provide some assistance on how to go about solving this?
After a look on the data sheet for the ADC0804 I found following which could be the/a possible reason:
Note: Read strobe must occur 8 clock periods (8/fCLK) after assertion of interrupt to guarantee reset of INTR.
Inserting a WAIT state between CONVERT and READ1 might fix the problem.